The 400 MHz NMR facility at BCE
Get certified in half an hour, place your tube in the changer, and your data arrives by email two minutes after the run ends.
Day queue is open until 18:00
For experiments under 35 minutes. First come, first served.
How it works
Three steps to your first spectrum
This is the whole workflow, from first visit to the data on your laptop. Each step takes less time than finding a parking spot at Gustav Wieds Vej.
Complete the induction course
Five short modules and a ten-question test, once, online. Pass at 90% and your TopSpin username is created within two working days.
Start the coursePrepare and submit your sample
A 178 × 5 mm tube, 600 µL of deuterated solvent, no particles, a clear label. Pick the day or night queue and place it in the changer.
Prep rules and queuesCollect your data
An email from data@bcenmr.dk arrives within two minutes of completion, with a Proton Drive backup. Process in MestreNova or TopSpin.
Data and software
The instrument
What you are working with
A research-grade Bruker Ascend Evo with a 9.4 tesla superconducting magnet and a SmartProbe that detects ¹H, ¹³C, ¹⁵N, ¹⁹F and ³¹P without a probe change. The 24-position SampleXpress changer loads, shims and ejects on its own, so experiments run unattended through the night and over the weekend.
Full specifications
- Magnet
- 9.4 T superconducting, actively shielded, cryo-cooled with near-zero drift
- Frequency
- 400 MHz for ¹H
- Probe
- SmartProbe BB/H/D with automatic tuning and matching
- Changer
- SampleXpress with 24 positions, automatic load, eject and shim
- Nuclei
- ¹H, ¹³C, ¹⁵N, ¹⁹F, ³¹P and other common NMR-active nuclei
- Operation
- Automated queue around the clock, unattended nights and weekends
- Data
- Emailed within two minutes of completion, backed up to Proton Drive
Prepare a sample
Five rules. No exceptions.
Every failed experiment traces back to one of these five steps. Tick them off before you walk to the lab.
Pre-flight checklist
0 of 5 checkedQueues
Day queue or night queue
Decide before you walk to the lab. Short runs go in the day queue, long runs in the night queue.
A 24-hour day at the changer
For experiments under 35 minutes. First come, first served. Place your sample during working hours and it runs in order.
For experiments of 35 minutes or longer, and for weekends. Place samples after 15:00 only, so the changer stays free for day users.
How long experiments take
| Experiment | Scans | Time | Queue |
|---|
Experiments
Find the right experiment
Pick the question you are asking. Only the matching experiments appear.
Pick a question above, or search, to see which experiments fit.
Solvents
Choosing a solvent
Pick a solvent to see the residual shifts to reference against and what it suits.
Pick a solvent above.
Compare all solvents in a table
| Solvent | Type | ¹H, ppm | ¹³C, ppm | Good for |
|---|
Get certified before you touch the instrument
Five modules, a sample-preparation simulation and a ten-question test. Pass at 90% for an instant certificate, with unlimited retries. About 35 minutes.
Your data
Delivered automatically
When the run ends, the data comes to you. Add data@bcenmr.dk to your safe senders so it never lands in spam.
- The run finishesIn the automated queue
- An email arrivesFrom data@bcenmr.dk, within two minutes
- You downloadDirect link to the Bruker folder
- You keep a copyThe backup is kept for a limited time only
MestreNova
Recommended for beginners. Download from mestrelab.com; the AU licence is on the iNANO website and needs the AU network or VPN.
TopSpin
Bruker's own software, free academic licence at bruker.com. Best for advanced processing and for looking at the raw FID.
Resources
Reference tables and tutorials
The few pages worth bookmarking.
- Hans Reich tablesChemical shift and coupling reference for structure work
- NMR PeaksFast chemical shift lookups
- Solvent impuritiesFulmer et al., residual and impurity peak tables
- UOttawa NMR blogPractical facility-level tips
- Beginner crash courseThe fundamentals in one sitting
- Advanced crash courseFor users who know the basics
Watch before your first run, three short videos
Which software should I use?
MestreNova if you are new: download from mestrelab.com, licence from the iNANO website on the AU network or VPN. TopSpin if you want the raw FID and advanced processing: free academic licence at bruker.com. Both open Bruker data directly.
Can I book the instrument for a specific time?
No. The queue is first come, first served and runs automatically. For unusual experiments or very long runs, contact Axel first.
Why does ¹³C need so much more sample than ¹H?
¹³C is 1% abundant; ¹H is 99.9%. Far fewer nuclei are visible per milligram. Signal-to-noise grows with the square root of the scan count, so doubling it needs four times the scans. More sample is nearly always the better fix.
My spectrum has broad peaks and a poor baseline. Why?
Almost always one of four things: particles in the tube, the wrong tube size, too little liquid, or a protonated solvent. Run through the five rules and resubmit.
Do I need a TopSpin username?
Yes, for every experiment in the automated queue. Axel creates it after you pass the induction course; the certificate email notifies him automatically.
Contact
Who to ask
Sample preparation, experiment choice, software or access. Ask before you get stuck; it saves everyone's instrument time.


Where
Department of Biological and Chemical Engineering, Aarhus University, Gustav Wieds Vej 10, 8000 Aarhus C
When
The queue runs around the clock. For in-person access or hands-on training, write to Axel to arrange a time.